Solus NX 16x8¶

Specifications¶
System¶
Sampling Rate: 48 kHz, ± 100 ppm
Frequency Response (A/D/A): 20 Hz – 20 kHz, ± 0.5 dB
Dynamic Range (A/D/A): > 110 dB (A-weighted), input to output
Channel Separation (A/D/A): > 90 dB @ 1 kHz, typical
THD+Noise: < -93 dB (unweighted); 1 kHz @ +22 dBu with 0 dB gain
Latency (A/D/A): < 1.6 mS, input routed to output
Processors: 1 x Analog Devices SHARC 21489 @ 400 MHz SIMD
Raw Processing Capacity: 400 MIPS, 1.6 GFLOPS
Delay Memory: 174 mono seconds
Analog control inputs: 0-3.3 VDC
Recommended External Control Potentiometer: 10k Ohm, linear
Logic Outputs: Low (0V) when active, pulled high (5V) when inactive
Logic Output Maximum External Power Supply Voltage: 24 VDC
Logic Output Maximum External Power Supply Current Sinking: 50 mA
Logic Output Maximum Output Current: 10 mA
RS-485 Serial I/O: 38.4 kbaud (default) 8 data bits, 1 stop bit, no parity, no flow control. May be broken out of ARC port
Ethernet Cable: Standard CAT5e or CAT6, maximum device-to-device length = 100 meters
ARC Cable: Standard CAT5, distance dependent upon load and number of devices. 8 Watts maximum power available
Maximum Stored Presets: 1000
Analog Inputs¶
Number of Inputs: Sixteen (16) switchable balanced mic or line level
Connectors: 3.81 mm terminal blocks
Nominal Input Level: +4 dBu line or -43 dBu mic level (software selectable) with 20 dB of headroom
Maximum Input Level: +23 dBu
Mic Pre-amp Gain: +40 dB switchable with ± 24 dB digital trim
Mic Pre-amp EIN: < -114 dBu, 22 Hz - 22 kHz, 100 Ω source impedance
CMRR: > 80 dB @ 1 kHz, unity gain
Input Impedance: > 18k Ohms balanced, > 9k Ohms unbalanced, > 2k Ohms with phantom power engaged
Phantom Power (per input): +20 VDC @ 20 mA maximum per input
Analog Outputs¶
Number of Outputs: Eight (8) balanced line level
Connectors: 3.81 mm terminal blocks
Nominal Output Level: +4 dBu with 20 dB of headroom
Maximum Output Level: +24 dBu (+22.8 dBu into a 2k Ohm minimum load)
Output Impedance: 200 Ohms balanced, 100 Ohms unbalanced
Dynamic Range: > 117 dB, A-weighted
THD+Noise: < -97 dB; 22.4 kHz BW, unweighted; 1 kHz, -6 dBFS gain +18dBu output
Mechanical Data¶
Space Required¶
1U (WDH: 18.91 in x 9.88 in x 1.72 in / 48.02 cm x 25.1 cm x 4.37 cm). Depth does not include connector allowance.
Allow at least 3 inches additional clearance for rear panel connections. Additional depth maybe required depending upon your specific wiring and connections.
Electrical¶
24V 1.4A, 34W Maximum
Symetrix Part Number 12-0034
CUI part number SDI65-24-U-P5
Ventilation¶
Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08 cm, 2 in minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc.
Certifications or Compliance¶
Safety: UL 60065, cUL 60065, IEC 60065
EMC: “Class A” device (applies to all of the following) EN 55032, EN 55103-2, EN 61000-3-2, EN 61000-3-3, FCC Part 15,
ICES-003
Environmental: RoHS
Shipping Weight¶
8.7 lbs. (3.9 kg)
A&E Specifications¶
The device shall provide sixteen analog inputs that are selectable as line or mic level with fine trim and phantom power plus eight analog line outputs that are adjustable with fine trim. Levels, phantom powers, signal inversions and mutes shall be controllable via software. Audio connections shall be accessed via rear panel 3.81 mm terminal block connectors.
A designer software application shall be provided that operates on a Windows computer, with network interface installed, running Windows® 7 or higher operating system. Computer connection for configuration shall be via the device’s rear panel Ethernet connector. All internal processing shall be digital (DSP). Available DSP components shall include (but not be limited to) various forms of: mixers, equalizers, filters, crossovers, dynamics/gain controls, routers, delays, remote controls, meters, generators, onboard logic, and diagnostics.
The front panel shall include an LCD and momentary switch. The display shall indicate unit name, IP address, MAC address, Site File version, and fault messages and can be switched between system overview and meter displays.
External control shall include dedicated software screens as well as preset selection, I/O level control and muting using the optional ARC wall panel remote controls via industry-standard CAT5 cable with RJ45 connectors. A built-in web server shall provide four instances of ARC-WEB, which allows for user control from nearly any web browser or mobile device. Logic I/O shall consist of four contact closure or two potentiometer inputs along with four logic outputs. The logic outputs may be used to drive LEDs directly or control external relays or switchers. All program memory shall be non-volatile and provide program security should power fail. The device shall provide an on-board real-time clock to facilitate automatic, timed changing of presets and may sync to NTP. Third-party control systems may interface over IP using a published ASCII control protocol.
Audio conversion shall be 24-bit, 48 kHz and internal processing shall be 32-bit or 40-bit floating point, 48 kHz. The dynamic range shall not be lower than 110 dB, A-weighted with a maximum input level of +23 dBu and maximum output level of +24 dBu.
The device shall have a power plug that accepts power from Symetrix part number 12-0034, CUI power supply part number SDI65-24-U-P5. The device shall meet UL/CSA and CE safety requirements and comply with CE and FCC Part 15 emissions limits. The device shall be RoHS compliant. The chassis shall be constructed of cold rolled steel, and mount into a standard 19” 1U EIA rack. The device shall be a SymetrixSolus NX 16x8.
Front Panel¶

Navigation Button: A single momentary push button is used to cycle through the Dashboard and System Pages or dismiss a fault notification. A short press scrolls through the menus or dismisses a fault notification and a long press toggles between the Dashboard and System Pages.
Dashboard: Shows either an overview of system parameters or input/output level meters. The overview contains limited information such as Unit Name, IP Address, DHCP Status, informational messages, and communication LEDs for Ethernet, and ARC. A short press moves between the overview and input/output meters. For 4x4 and 8x8 devices, both the input and output meters are shown on a single page. For larger devices, input meters are shown on one page and output meters on a second page.
The meters are scaled from -72 dBFS to 0 dBFS. Each segment represents 12 dB. A good rule of thumb is to aim for typical signal levels reaching just into the second highest segment and peaks occasionally entering the highest segment. If the signal reaches clipping, the meter will get wider.
The on screen status LEDs display the following information:
-
ARC LED:
-
- Empty oval = No ARC Connected
- Oval with dot in the center = Physical RS485 ARC device is connected (ARC-2e, ARC-K1e, etc.)
- Solid Oval = Flashes when an ARC, physical or virtual (ARC-WEB, ARC-FP, ARC-K1e, etc.), communicates with the device
-
! = Flashes when an ARC is disconnected
-
Network LED:
-
- Empty oval = Nothing connected or no network communication
- Solid oval = Flashes for network communication (often this is so constant it will be solid)
- Oval with dot in the center = Device looking for IP address in DHCP mode
- ! = Ethernet Cable Removed or hardware access code invalid
System Pages: Contain detailed system information including Device Name, DHCP Status, IP Address, Subnet Mask, Gateway Address, NTP Address, MAC Address, Firmware Version, Motherboard Temperature, Motherboard Maximum Temperature, Motherboard Minimum Temperature, Fan Speed, Site File Version, and Site ID.
Faults: Faults are displayed for high temperature, power supply problems, and fan failure. Faults will “take over” the display regardless of what else is visible. A short press dismisses a fault message. However, if the fault is still occurring, it will be displayed again shortly.
Rear Panel¶
ARC: Distributes power and RS-485 data to one or more ARC devices.
Ethernet: 10/100 Base-T Ethernet port for Symetrix Composer host control, and third party accessory controllers over IP. Features auto-crossover sensing for direct device-to-device connections.
Factory Reset Switch: To be used under the supervision of technical support, it has the ability to reset the unit’s network configuration and completely reset the unit to factory defaults.
Logic Outputs: Four (4) logic outputs with two (2) paired common ground pins. Logic Outputs go low (0V) when active, and are internally pulled high (5V) when inactive and can drive external LED indicators directly.
External Control Inputs: Two (2) analog control inputs able to be used as 2 potentiometer inputs or as 4 switch inputs (+3.3 VDC reference voltage supplied).
Analog Line Outputs: Sixteen (16) balanced analog line level audio outputs, with individually software-controllable +/- 24 dB of digital trim and mute.
Analog Mic/Line Inputs: Eight (8) balanced analog audio inputs, with individually software-controllable pre-amp gain (reference levels of -50 dBu, -40 dBu, -20 dBu, -10 dBV and +4 dBu), +/- 24 dB of digital trim, phantom power, signal inversion and mute.